Power Up the Flight Operations and MAintenance eXchanger (FOMAX) with the Circuit Breaker
TASK 46-26-32-860-808-A
Power Up the Flight Operations and MAintenance eXchanger (FOMAX) with the Circuit Breaker
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-26-32-861-076-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-865-082-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-410-069-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:07 UTC
Power Up the Flight Operations and MAintenance eXchanger (FOMAX) with the Circuit Breaker
ZONE: 128
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 128 | REAR AVIONIC COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 46-26-32-860-804-A | Access to the LEDs of the Flight Operations and MAintenance eXchanger (FOMAX) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 46-26-32-861-076-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 46-26-32-010-065-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 824.
(2) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 46-26-32-865-082-A ** ON A/C NOT FOR ALL
A. Close this(these) circuit breaker(s):
Subtask 46-26-32-010-066-A ** ON A/C NOT FOR ALL Subtask 46-26-32-210-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | J01 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | R12 |
C. Do a check of the FOMAX LEDs, when FOMAX start-up is complete, the green LED is on and the amber LED is off.
5. Close-upSubtask 46-26-32-410-069-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).
(3) Remove the access platform(s).