W DOC AIRBUS | AMM A320F

Deactivation of the Pack Flow-Control Valve


TASK 21-51-00-040-001-A
Deactivation of the Pack Flow-Control Valve


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
NOTE: The procedure is the same for the pack flow-control valve 8HB and 11HB.
FIN: 11HB ** ON A/C NOT FOR ALL
FIN: 8HB ** ON A/C NOT FOR ALL
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
YESYESNO0.50.51
1. Reason for the Job
MMEL 21-51-01A
PACK FLOW CONTROL VALVE
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [11HB] (P1 FLOW CTL VALVE)
191KB
FOR [8HB] (P2 FLOW CTL VALVE)
192KB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 53-35-13-000-002-A
Removal of the Quick-Release Access Panels from the Belly Fairing Structure
TASK 53-35-13-400-002-A
Installation of the Quick-Release Access Panels on the Belly Fairing Structure
3. Job Set-up
Subtask 21-51-00-861-050-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits. (Ref. AMM TASK 24-41-00-861-002)
Subtask 21-51-00-010-051-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Remove the access panel (Ref. AMM TASK 53-35-13-000-002):
     (a) FOR [8HB] (P2 FLOW CTL VALVE)
     (b) FOR [11HB] (P1 FLOW CTL VALVE)
Subtask 21-51-00-941-051-A ** ON A/C NOT FOR ALL
C. Safety Precautions
   (1) On the panel 30VU:
     (a) Make sure that:
  • the APU BLEED pushbutton switch is in the off position (the ON legend is off) and,
  • the ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are in the off position (the OFF legends are on).
     (b) Put a warning notice in position to tell persons not to operate these switches.
   (2) On the HP ground connector put a warning notice in position to tell persons not to supply the ground air.
4. Procedure
Subtask 21-51-00-040-050-B ** ON A/C NOT FOR ALL
A. Deactivation of the Pack Flow-Control Valve
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS.
   (1) FOR [11HB] (P1 FLOW CTL VALVE)
     (a) Push the PACK 1 pushbutton switch to the off position (the OFF legend comes on).
   (2) FOR [8HB] (P2 FLOW CTL VALVE)
     (a) Push the PACK 2 pushbutton switch to the off position (the OFF legend comes on).
   (3) Remove and discard the lockwire from the special screw (1).
   (4) Remove the special screw (1) from the position (A).
   (5) Disconnect the quick release connector (3).
NOTE: This will open the pack flow-control valve and close the butterfly valve.
   (6) Make sure that the valve indicator (2) is in the closed position.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (7) Install the special screw (1) in the position (B) and safety with dia. 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (8) Connect the quick release connector (3) to the connection (4).
5. Close-up
Subtask 21-51-00-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the access panel (Ref. AMM TASK 53-35-13-400-002) :
     (a) FOR [8HB] (P2 FLOW CTL VALVE)
     (b) FOR [11HB] (P1 FLOW CTL VALVE)
   (3) Remove the WARNING NOTICE(S).
   (4) Record the deactivation of the pack flow-control valve in the aircraft technical log book.
Subtask 21-51-00-862-050-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits. (Ref. AMM TASK 24-41-00-862-002)
[Rev.10 from 2021] 2026.04.05 07:03:07 UTC