FIN: (5HV) P/BSW-AIR COND/APU BLEED
AMM TASK
- APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS
-
36-12-00-615-804-A
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1,4000HA2) with the APU Bleed Pressure
-
36-12-00-615-804-A-01
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
-
36-12-00-615-804-A-02
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
-
36-12-00-615-807-A
Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure
-
36-12-00-860-001-A
Pressurization of the Bleed System with the APU
-
36-12-00-860-002-A
Pressurization of the Bleed System through the HP Ground Connector
-
36-12-00-615-802-A
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
-
36-12-00-615-802-A-01
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-615-802-A-02
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-615-802-A-03
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
-
36-12-00-615-806-A
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure
-
36-12-00-615-806-A-01
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
-
36-12-00-615-806-A-02
Decontamination of the Bleed-Air Ducting System disconnected at the Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
-
36-12-00-615-808-A
Decontamination of the Bleed-Air Ducting System Disconnected at HP Ground Connector with the APU Bleed Pressure
-
36-12-00-860-802-A
Pressurization of the Bleed System with the APU
-
36-12-00-860-803-A
Pressurization of the Bleed System through the HP Ground Connector
-
36-12-00-860-804-A
Pressurization of the Bleed System from a Second Aircraft
-
36-12-00-615-803-A
Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 1 Bleed Pressure
-
36-12-00-615-803-A-01
Decontamination of the Bleed-Air Ducting System Disconnected at the APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-040-808-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-810-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-811-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-440-805-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-807-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-808-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-040-801-A
Deactivation of the APU Bleed Check-Valve
-
36-12-00-040-804-A
Inspection of the APU Bleed Check-Valve for Correct Condition
-
36-12-00-440-801-A
Reactivation of the APU Bleed Check-Valve
-
36-12-00-040-813-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-815-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-820-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-440-813-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-815-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-820-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-040-802-A
Deactivation of the APU Bleed Check-Valve
-
36-12-00-440-802-A
Reactivation of the APU Bleed Check-Valve
-
36-12-00-040-805-A
Inspection of the APU Bleed Check-Valve for Correct Condition
-
36-12-00-710-001-A
Operational Test of the APU Bleed Air Supply and Crossbleed Systems
-
36-12-00-710-002-A
Operational Check of Crossbleed Valve in Manual Mode
-
36-12-00-790-001-A
Leak Test of the APU Bleed-Air Supply-System
-
36-12-00-790-002-A
Perform Leak Check on APU Bleed Air Ducting (Upstream the APU Bleed Check Valve)
-
36-12-00-790-003-A
Leak Check of Bleed Air Ducting in the Fuselage Area between the APU Bleed Check Valve, Air Conditioning Pack and Wing/Fuselage Connection
-
36-12-00-615-805-A
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1, 4000HA2) with the APU Bleed Pressure
-
36-12-00-615-805-A-01
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA1) with the APU Bleed Pressure
-
36-12-00-615-805-A-02
Decontamination of the Bleed-Air Ducting System Disconnected at Pressure Regulating Valve (PRV) (4000HA2) with the APU Bleed Pressure
-
36-12-00-615-809-A
Decontamination of the Bleed-Air Ducting System through HP Ground Connector with the APU Bleed Pressure
-
36-12-00-860-805-A
Pressurization of the Bleed System with the APU
-
36-12-00-860-806-A
Pressurization of the Bleed System through the HP Ground Connector
-
36-12-00-615-801-A
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 1 Bleed Pressure
-
36-12-00-615-801-A-01
Decontamination of the Bleed-Air Ducting System Disconnected at APU Load-Compressor Valve with Engine 2 Bleed Pressure
-
36-12-00-040-814-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-819-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-040-821-A
Deactivation of the APU Leak-Detection Loop
-
36-12-00-440-814-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-819-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-440-821-A
Reactivation of the APU Leak-Detection Loop
-
36-12-00-040-803-A
Deactivation of the APU Bleed Check-Valve
-
36-12-00-440-803-A
Reactivation of the APU Bleed Check-Valve
-
36-12-00-040-806-A
Inspection of the APU Bleed Check-Valve for Correct Condition