W DOC AIRBUS | AMM A320F

Removal of the Push-Pull Cable [CFML]


TASK 71-13-41-000-804-A
Removal of the Push-Pull Cable


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: MAKE SURE THAT THE SLATS ARE RETRACTED AND INHIBITED. MOVEMENT OF THE SLATS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
ZONE: 400
FIN: 4205KM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
AR
WARNING NOTICE(S)
98D27803500001
1
LOCKING TOOL ZERO POS
98D27803500002
1
LOCKING TOOL ZERO POS
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 27-80-00-866-005-A
Retracting the Slats on the Ground
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
3. Job Set-up
Subtask 71-13-41-941-060-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch,
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
   (3) Make sure that the slats are in the fully retracted position (Ref. AMM TASK 27-80-00-866-005).
   (4) Install the 98D27803500001 LOCKING TOOL ZERO POS or 98D27803500002 LOCKING TOOL ZERO POS on the flap and slat control lever on panel 114VU.
Subtask 71-13-41-010-059-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR.
Subtask 71-13-41-010-065-A
C. Get Access
   (1) Get access to the latch detection assembly inside the LH fan cowl door.
   (2) Put an ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure
Subtask 71-13-41-020-056-A
WARNING: USE PROTECTIVE GOGGLES WHEN YOU REMOVE OR INSTALL A COTTER PIN. EACH TIME YOU REMOVE A COTTER PIN DURING THE TASK, DISCARD IT IMMEDIATELY. A LOOSE COTTER PIN CAN CUT YOU OR MAKE YOU BLIND.
A. Removal of the Push-Pull Cable

PRE SPOL BD-FC-18003

   (1) At the lower end of the push-pull cable (1), remove the cotter pin (3), washer (2) and pin (4) from the lever assy (12). Discard the cotter pin (3).
   (2) Remove the bolts (11) and the washers (10).
   (3) Keep the clamps (9) installed on the push-pull cable (1).
   (4) At the upper end of the push-pull cable (1), remove the cotter pin (3), washer (2) and pin (4). Discard the cotter pin (3).
   (5) Record the position of the upper end of the push-pull cable (1) to install it in the same position.
   (6) Removal of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Cut, remove and discard the two lockwires (6).
   (7) Loosen the push-pull cable nuts (8) and (5).
   (8) Keep the washers (7) in position.
   (9) Remove the push-pull cable (1).

END OF PRE SPOL BD-FC-18003

Subtask 71-13-41-020-059-A
WARNING: USE PROTECTIVE GOGGLES WHEN YOU REMOVE OR INSTALL A COTTER PIN. EACH TIME YOU REMOVE A COTTER PIN DURING THE TASK, DISCARD IT IMMEDIATELY. A LOOSE COTTER PIN CAN CUT YOU OR MAKE YOU BLIND.
B. Removal of the Push-Pull Cable

POST SPOL BD-FC-18003

   (1) At the lower end of the push-pull cable (1), remove the cotter pin (3), washer (2) and pin (4) from the lever assy (12). Discard the cotter pin (3).
   (2) Remove the bolts (11) and the washers (10).
   (3) Keep the clamps (9) installed on the push-pull cable (1).
   (4) At the upper end of the push-pull cable (1), remove the cotter pin (3), washer (2) and pin (4). Discard the cotter pin (3).
   (5) Record the position of the upper end of the push-pull cable (1) to install it in the same position.
   (6) Removal of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Cut, remove and discard the lockwire (6).
   (7) Loosen the push-pull cable nuts (8) and (5).
   (8) Keep the washers (7) in position.
   (9) Remove the push-pull cable (1).

END OF POST SPOL BD-FC-18003

[Rev.10 from 2021] 2026.04.02 07:32:02 UTC