Special Detailed Inspection of the Inboard Flap, Internal Brackets at Track 2 LH/RH
TASK 57-52-00-220-008-A
Special Detailed Inspection of the Inboard Flap, Internal Brackets at Track 2 LH/RH
Refer to the MPD TASK: 575206-01
SPECIAL DETAILED INSPECTION (ENDOSCOPE) OF INBOARD FLAP, INTERNAL BRACKETS AT TRACK 2, LH/RH
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-52-00-941-066-A ** ON A/C NOT FOR ALL
Subtask 57-52-00-410-064-C ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:17 UTC
Special Detailed Inspection of the Inboard Flap, Internal Brackets at Track 2 LH/RH
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
1. Reason for the JobRefer to the MPD TASK: 575206-01
SPECIAL DETAILED INSPECTION (ENDOSCOPE) OF INBOARD FLAP, INTERNAL BRACKETS AT TRACK 2, LH/RH
NOTE: The effectivity of this task is ALL. To know if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 581 | FLAP N° 1 |
| 681 | FLAP N° 1 |
| 531AT, 531CB, 631AT, 631CB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 57-55-11-000-001-A | Removal of the Flap Track Fairings Nos. 2, 3 and 4 |
| TASK 57-55-11-400-001-A | Installation of the Flap Track Fairings Nos. 2, 3 and 4 |
| NTM 575206 | |
| SRM 575200 | (for corrective action) |
Subtask 57-52-00-941-066-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-52-00-860-103-A ** ON A/C NOT FOR ALL (1) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Aircraft Maintenance Configuration
(1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever.
Subtask 57-52-00-865-080-A ** ON A/C NOT FOR ALL (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
(2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 57-52-00-010-064-C ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
D. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable wing trailing edge at flap track 2, zone 531(631).
(2) Remove the access panel 531AT ( 631AT) and the flap track 2 fairing 531CB ( 631CB) (Ref. AMM TASK 57-55-11-000-001).
Subtask 57-52-00-110-075-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable wing trailing edge at flap track 2, zone 531(631).
(2) Remove the access panel 531AT ( 631AT) and the flap track 2 fairing 531CB ( 631CB) (Ref. AMM TASK 57-55-11-000-001).
E. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do the inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no TPS layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do the inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no TPS layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
Subtask 57-52-00-280-055-C ** ON A/C NOT FOR ALL - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
A. Inspection
(1) Do a special detailed inspection of the internal bracket of the inboard flap at track 2 LH/RH NTM 575206.
5. Close-up(1) Do a special detailed inspection of the internal bracket of the inboard flap at track 2 LH/RH NTM 575206.
NOTE: If necessary, refer to the SRM 575200 for the correct repair procedure. If the defect is not included in this repair, you must request a procedure from AIRBUS.
Subtask 57-52-00-410-064-C ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the flap track 2 fairing 531CB ( 631CB) and the access panel 531AT ( 631AT) (Ref. AMM TASK 57-55-11-400-001).
Subtask 57-52-00-865-081-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the flap track 2 fairing 531CB ( 631CB) and the access panel 531AT ( 631AT) (Ref. AMM TASK 57-55-11-400-001).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-52-00-860-104-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
C. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever.
(3) Retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-52-00-942-065-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever.
(3) Retract the flaps (Ref. AMM TASK 27-50-00-866-009).
D. Removal of Equipment
(1) Remove the access platform(s).
(2) Remove the WARNING NOTICE(S).
(3) Remove the safety barriers.
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the access platform(s).
(2) Remove the WARNING NOTICE(S).
(3) Remove the safety barriers.
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Flap Track 2 - Internal Bracket - Location