W DOC AIRBUS | AMM A320F

General Visual Inspection of Inboard Double-Slotted Flap, External Surface of Upper and Lower Skin, LH/RH


TASK 57-52-00-210-009-A
General Visual Inspection of Inboard Double-Slotted Flap, External Surface of Upper and Lower Skin, LH/RH


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
ZONE: 581
ZONE: 681
1. Reason for the Job
Refer to the MPD TASK: 575221-01
GENERAL VISUAL INSPECTION OF INBOARD DOUBLE-SLOTTED FLAP, EXTERNAL SURFACE OF UPPER AND LOWER SKIN, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98D27803000000
1
LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
581
FLAP N° 1
681
FLAP N° 1
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
SRM 575200
(for corrective action)
3. Job Set-up
Subtask 57-52-00-941-084-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-52-00-860-107-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever (panel 114VU).
   (3) Put a WARNING NOTICE(S) in position on the flap/slat control lever to tell persons not to operate the flaps.
Subtask 57-52-00-865-113-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-52-00-010-087-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the applicable zone 581 (681).
4. Procedure
Subtask 57-52-00-100-051-A ** ON A/C NOT FOR ALL
A. Preparation for Inspection
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the applicable area for inspection.
Subtask 57-52-00-210-067-A ** ON A/C NOT FOR ALL
B. General Visual Inspection of Inboard Double-Slotted Flap, External Surface of Upper and Lower Skin, LH/RH
   (1) Do an inspection of the upper and lower skin external surface of the inboard double-slotted flap, LH/RH. Make sure that:
  • there is no damage
  • there are no cracks
  • there is no corrosion
  • the paint finish is in the correct condition.
NOTE: If necessary, refer to the SRM 575200 for the correct repair procedure.
5. Close-up
Subtask 57-52-00-865-114-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-52-00-860-108-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-52-00-942-082-A ** ON A/C NOT FOR ALL
C. Removal of Equipment
   (1) Remove the access platform(s).
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 06:31:18 UTC