W DOC AIRBUS | AMM A320F

Self-Test of the Flight Operations and MAintenance eXchanger (FOMAX) with the Local Maintenance Function (LMF)


TASK 46-26-32-700-801-A
Self-Test of the Flight Operations and MAintenance eXchanger (FOMAX) with the Local Maintenance Function (LMF)


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
072-3175-001
1
FOMAX LMF
072-3175-003
1
FOMAX LMF
072-3175-004
1
FOMAX LMF
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 46-26-32-860-801-A
Connection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) to the Flight Operations and MAintenance eXchanger (FOMAX)
TASK 46-26-32-860-805-A
Reset of the Flight Operations and MAintenance eXchanger (FOMAX) with the Local Maintenance Function (LMF)
TASK 46-26-32-860-806-A
Disconnection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) from the Flight Operations and MAintenance eXchanger (FOMAX)
3. Job Set-up
Subtask 46-26-32-861-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 46-26-32-860-057-A ** ON A/C NOT FOR ALL
B. Connect the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) to the FOMAX (Ref. AMM TASK 46-26-32-860-801).
4. Procedure
Subtask 46-26-32-710-052-A ** ON A/C NOT FOR ALL
A. Self-Test of the FOMAX with the LMF
   (1) Do a reset of the FOMAX (Ref. AMM TASK 46-26-32-860-805).
   (2) On the 072-3175-001 FOMAX LMF or the 072-3175-003 FOMAX LMF or the 072-3175-004 FOMAX LMF display, on the "FOMAX Internal" page, make sure that the LED adjacent to the "FOMAX Internal" button is green.
Subtask 46-26-32-710-052-B ** ON A/C NOT FOR ALL
A. Self-Test of the FOMAX with the LMF
   (1) Do a reset of the FOMAX (Ref. AMM TASK 46-26-32-860-805).
   (2) On the 072-3175-003 FOMAX LMF or the 072-3175-004 FOMAX LMF display, on the "FOMAX Internal" page, make sure that the LED adjacent to the "FOMAX Internal" button is green.
Subtask 46-26-32-710-052-CS ** ON A/C NOT FOR ALL
A. Self-Test of the FOMAX with the LMF
   (1) Do a reset of the FOMAX (Ref. AMM TASK 46-26-32-860-805).
   (2) On the 072-3175-004 FOMAX LMF display, on the "FOMAX Internal" page, make sure that the LED adjacent to the "FOMAX Internal" button is green.
5. Close-up
Subtask 46-26-32-860-069-A ** ON A/C NOT FOR ALL
A. Disconnect the Maintenance Electronic Device (with the LMF) from the FOMAX (Ref. AMM TASK 46-26-32-860-806).
Subtask 46-26-32-862-056-A ** ON A/C NOT FOR ALL
B. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:26:09 UTC