Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Local Maintenance Function (LMF)
TASK 46-26-32-280-801-A-01
Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Local Maintenance Function (LMF)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 46-26-32-861-061-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-280-054-A ** ON A/C NOT FOR ALL
Subtask 46-26-32-860-067-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:08 UTC
Check of the Flight Operations and MAintenance eXchanger (FOMAX) Configuration with the Local Maintenance Function (LMF)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 46-26-32-860-801-A | Connection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) to the Flight Operations and MAintenance eXchanger (FOMAX) |
| TASK 46-26-32-860-806-A | Disconnection of the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) from the Flight Operations and MAintenance eXchanger (FOMAX) |
Subtask 46-26-32-861-061-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 46-26-32-865-064-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 46-26-32-860-065-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FOMAX | 67TA | J01 |
C. Connect the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) to the FOMAX (Ref. AMM TASK 46-26-32-860-801).
4. ProcedureSubtask 46-26-32-280-054-A ** ON A/C NOT FOR ALL
A. Check of the FOMAX Configuration with the LMF
5. Close-up| ACTION | RESULT |
|---|---|
| 1.Make sure that you started the LMF on the maintenance electronic device that is connected to the FOMAX. | |
2.On the LMF Main page:
| On the LMF:
|
3.On the LMF, on the "FOMAX Internal" page:
| On the LMF:
|
Subtask 46-26-32-860-067-A ** ON A/C NOT FOR ALL
A. Disconnect the Maintenance Electronic Device (with the Local Maintenance Function (LMF)) from the FOMAX (Ref. AMM TASK 46-26-32-860-806).
Subtask 46-26-32-862-061-A ** ON A/C NOT FOR ALL