Removal of the Magnetic Level-Indicator Assembly
TASK 28-43-22-000-002-A
Removal of the Magnetic Level-Indicator Assembly
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 28-43-22-941-051-A ** ON A/C NOT FOR ALL
Subtask 28-43-22-020-051-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:18:13 UTC
Removal of the Magnetic Level-Indicator Assembly
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | 1 | SAFETY BARRIER(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [64QM] (HOUSING-MLI, L WING TK OUTR) | |
| 540RB | |
| FOR [65QM] (HOUSING-MLI, R WING TK OUTR) | |
| 640RB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 57-27-11-000-002-A | Removal of the Access Panel |
| (for corrective action) | |
Subtask 28-43-22-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(2) Put the SAFETY BARRIER(S) in position.
Subtask 28-43-22-650-050-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) You must obey the fuel safety procedures when you do work in a fuel tank (Ref. AMM TASK 28-10-00-910-001). (2) Put the SAFETY BARRIER(S) in position.
B. Fuel Configuration
(1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
Subtask 28-43-22-010-050-A ** ON A/C NOT FOR ALL (1) Defuel the applicable fuel tank (Ref. AMM TASK 28-25-00-650-001).
(2) Drain the remaining fuel from the applicable fuel tank (Ref. AMM TASK 28-25-00-650-003).
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 540RB (640RB).
(2) Remove the access panel (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [64QM] (HOUSING-MLI, L WING TK OUTR)
remove 540RB
(b) FOR [65QM] (HOUSING-MLI, R WING TK OUTR)
remove 640RB.
4. Procedure(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the applicable access panel 540RB (640RB).
(2) Remove the access panel (Ref. AMM TASK 57-27-11-000-002) and (Ref. AMM TASK 28-10-00-910-002):
(a) FOR [64QM] (HOUSING-MLI, L WING TK OUTR)
remove 540RB
(b) FOR [65QM] (HOUSING-MLI, R WING TK OUTR)
remove 640RB.
Subtask 28-43-22-020-051-B ** ON A/C NOT FOR ALL
A. Removal of the Magnetic Level-Indicator Assembly 64QM (65QM)
(1) Remove the nuts (3) from the bolts (6).
(2) Remove the bolts (6) from the magnetic level-indicator housing (2).
(3) Remove the magnetic level-indicator assembly (7) from the access panel.
(1) Remove the nuts (3) from the bolts (6).
(2) Remove the bolts (6) from the magnetic level-indicator housing (2).
(3) Remove the magnetic level-indicator assembly (7) from the access panel.
NOTE: If the MLI is removed with a loose or damaged top-stop (8), refer to CMM 284330 for repair instructions.
(4) Remove and discard the O-ring seals (4) and (5).
Magnetic-Level-Indicator Assembly