W DOC AIRBUS | AMM A320F

Scheduled Replacement of the Trailing-Edge Probe Filter of the Pack Flow-Control Valve


TASK 21-51-51-600-001-A
Scheduled Replacement of the Trailing-Edge Probe Filter of the Pack Flow-Control Valve


FIN: 11HB ** ON A/C NOT FOR ALL
FIN: 8HB ** ON A/C NOT FOR ALL
1. Reason for the Job
To replace a contaminated trailing-edge probe filter of the pack flow-control valve.
NOTE: This procedure is only applicable for the pack flow-control valves that follow:
  • The P/N 751F0000-01
  • The P/N 751G0000-01.
NOTE: This procedure is not applicable for these pack flow-control valves:
  • P/N 751A-Amdt C
  • P/N 751B-Amdt B.
    The A-and B-type filters can not be replaced on aircraft.
The procedure is the same for the pack flow-control valves 8HB and 11HB.
For recommendations as to the intervals refer to Liebherr SB 751-21-01.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 21-51-00-710-002-A
Operational Test of the Flow Control and Indicating System
3. Job Set-up
Subtask 21-51-51-865-058-A
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 11HB (P1 FLOW CTL VALVE)
49VUAIR COND/FLOW/CTL &/IND11HBD07
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
FOR FIN: 8HB (P2 FLOW CTL VALVE)
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
4. Procedure
WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: DO NOT TOUCH THE COMPONENT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS.
Subtask 21-51-51-865-059-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 11HB (P1 FLOW CTL VALVE)
49VUAIR COND/FLOW/CTL &/IND11HBD07
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
FOR FIN: 8HB (P2 FLOW CTL VALVE)
122VUAIR COND/FLOW/CTL AND IND/22HBV21
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
Subtask 21-51-51-710-051-A
B. Test and Check
   (1) Do the operational test of the flow control and indicating system (Ref. AMM TASK 21-51-00-710-002).
   (2) Leak Check
WARNING: PUT ON PROTECTIVE GOGGLES AND THERMAL GLOVES WHEN YOU GO NEAR AN AIR-CONDITIONING PACK WHEN IT OPERATES. THERE CAN BE LEAKAGE OF HOT AIR, WHICH CAN CAUSE INJURIES.
     (a) During the operational test, do a check for leaks at the filter installation.
NOTE: Leaks are not permitted.
[Rev.10 from 2021] 2026.04.02 06:11:23 UTC