AVIONICS EQUIPMENT VENTILATION
-
21-26-01 AVIONICS EQUIPMENT VENTILATION - INSTL
-
21-26-01-01A DUCTING INSTL-BLOWING
Zone(s): 210
-
21-26-01-01B DUCTING INSTL-BLOWING
Zone(s): 210
-
21-26-01-02K DUCTING INSTL-BLOWING
Zone(s): 120
-
21-26-01-02P DUCTING INSTL-BLOWING
Zone(s): 120
-
21-26-01-02Q DUCTING INSTL-BLOWING
Zone(s): 120
-
21-26-01-03L DUCTING INSTL-BLOWING FR20-25
Zone(s): 127
128
-
21-26-01-03U DUCTING INSTL-BLOWING FR20-25
Zone(s): 127
128
-
21-26-01-04A SWITCH INSTL-PRESSURE,FR4-TO-FR7
Zone(s): 121
-
21-26-01-05 VALVE INSTL-CHECK,FR20-TO-FR21
Zone(s): 128
-
21-26-01-06B FILTER INSTL-FR20-21
Zone(s): 127
-
21-26-01-06C FILTER INSTL-FR20-21
Zone(s): 127
-
21-26-01-07 SWITCH INSTL-PRESSURE,FR23-TO-FR24
Zone(s): 127
-
21-26-01-07A SWITCH INSTL-PRESSURE,FR23-TO-FR24
Zone(s): 127
-
21-26-01-08A FAN INSTL-FR20-21
Zone(s): 128
-
21-26-01-08B FAN INSTL-FR20-21
Zone(s): 128
-
21-26-01-09 VALVE INSTL-BUTTERFLY,FR21-TO-FR22
Zone(s): 127
-
21-26-01-10A SENSOR INSTL-DUCT TEMP,FR21-TO-FR23
Zone(s): 127
-
21-26-01-11A VALVE INSTL-SKIN AIR,FR12-22
Zone(s): 127
-
21-26-01-12A DUCTING INSTL-EXTRACT
Zone(s): 210
-
21-26-01-13A DUCTING INSTL-EXTRACT,FR1-18
Zone(s): 120
-
21-26-01-13B DUCTING INSTL-EXTRACT,FR1-18
Zone(s): 120
-
21-26-01-14D DUCTING INSTL-EXTRACTION,FR18-TO-FR24
-
21-26-01-14E DUCTING INSTL-EXTRACTION, FR18-TO-FR24
-
21-26-01-14F DUCTING INSTL-EXTRACTION,FR18-TO-FR24
-
21-26-01-14H DUCTINS INSTL-EXTRACTION,FR18-TO-FR24
-
21-26-01-15 VALVE INSTL-SKIN AIR,FR17-18
Zone(s): 126
-
21-26-01-16 SWITCH INSTL-PRESSURE,FR21
Zone(s): 128
-
21-26-01-17 EQUIPMENT INSTL
Zone(s): 126
127
128
-
21-26-01-18A DUCTING INSTL-RECIRCULATION
Zone(s): 120
130
140
150
160
170
190
210
-
21-26-01-21 VALVE INSTL-BUTTERFLY AIR,FR15
Zone(s): 125
-
21-26-01-22B SENSOR INSTL-SKIN TEMP,FR11-12
Zone(s): 126
-
21-26-01-23 DUCTING INSTL-BAT VENTILATION
Zone(s): 126
-
21-26-01-24 DUCTING INSTL-CENTER PEDESTAL VENT
Zone(s): 210
-
21-26-01-27B DUCTING INSTL-BLOWING FR20-25
Zone(s): 127
128
-
21-26-01-29 SENSOR INSTL-DUCT TEMP,FR23-24
Zone(s): 120
-
21-26-08 AVIONICS EQUIPMENT VENTILATION - INSTL
-
21-26-11 PRESSURE SWITCHES - BLOWER AND EXTRACT FAN
-
21-26-12 SENSOR - DUCT TEMPERATURE
-
21-26-13 SENSOR - SKIN TEMPERATURE
-
21-26-34 COMPUTER - AVIONICS EQUIPMENT VENTILATION (AEVC)
-
21-26-41 CHECK VALVE
-
21-26-43 FILTER - DEMISTER
-
21-26-51 FANS - EXTRACT AND BLOWER
-
21-26-52 VALVE - SKIN AIR INLET
-
21-26-53 VALVE - SKIN AIR OUTLET
-
21-26-54 VALVE - CONDITIONED AIR INLET
-
21-26-55 VALVES - SKIN EXCHANGER
-
21-26-56 CHECK VALVE - AIR INLET
-
21-26-81 AVIONICS EQUIPMENT VENTILATION
-
21-26-81-01 DUCTING INSTL-BLOWING
Zone(s): 210
-
21-26-81-02B DUCTING INSTL-BLOWING
Zone(s): 120
-
21-26-81-03D DUCTING INSTL-BLOWING FR20-25
Zone(s): 120
-
21-26-81-04A SWITCH INSTL-PRESSURE,FR3-4
Zone(s): 120
-
21-26-81-05 VALVE INSTL-CHECK,FR20-21
Zone(s): 120
-
21-26-81-06A FILTER INSTL-FR20-21
Zone(s): 120
-
21-26-81-07 SWITCH INSTL-PRESSURE,FR23-24
Zone(s): 120
-
21-26-81-08 FAN INSTL-FR20-21
Zone(s): 120
-
21-26-81-09 VALVE INSTL-BUTTERFLY,FR21-23
Zone(s): 120
-
21-26-81-10 SENSOR INSTL-DUCT TEMP,FR21-23
Zone(s): 120
-
21-26-81-11 VALVE INSTL-SKIN AIR,FR12-22
Zone(s): 127
-
21-26-81-12 DUCTING INSTL-EXTRACT
Zone(s): 210
-
21-26-81-13 DUCTING INSTL-EXTRACT,FR1-18
Zone(s): 120
-
21-26-81-14 DUCTING INSTL-EXTRACT,FR18-24
Zone(s): 120
-
21-26-81-15 VALVE INSTL-SKIN AIR,FR18-17
Zone(s): 126
-
21-26-81-16 SWITCH INSTL-PRESSURE,FR21
Zone(s): 128
-
21-26-81-17 EQUIPMENT INSTL
Zone(s): 120
-
21-26-81-18A DUCTING INSTL-RECIRCULATION
Zone(s): 120
210
-
21-26-81-18B DUCTING INSTL-RECIRCULATION
Zone(s): 120
210
-
21-26-81-21 VALVE INSTL-BUTTERFLY AIR,FR15
Zone(s): 120
-
21-26-81-22 SENSOR INSTL-SKIN TEMP,FR11-12
Zone(s): 120
-
21-26-81-23 DUCTING INSTL-BAT VENTILATION
Zone(s): 120
-
21-26-81-24 DUCTING INSTL-CENTER PEDESTAL VENT
Zone(s): 210
-
21-26-81-29 SENSOR INSTL-DUCT TEMP,FR23-24
Zone(s): 120
-
21-26-88 AVIONICS EQUIPMENT VENTILATION